Use the filters to find the tests that you need or search by name.
Direct water analysis by combustion/oxidation method
Water extraction 72h at 50°C, GC-MS screening
Multiple cycles per customer, gravimetric measurement
Direct GC-MS with BSTFA derivatization
Method validation with count standards at 10µm and 25µm
XRF analysis for Pb, Cd, As in food contact materials
GC-MS analysis for butanediol diglycidyl ether
Direct measurement at 25°C with conductivity cell
IPA extraction, LC-MS non-volatile screening
Direct GC-MS analysis for 13 phthalates
Hexane extraction 24h, GC-MS quantification
Water extraction, semi-quantitative scan for 40 elements
Solvent extraction, GC-MS for 13 phthalate esters
Extraction then GC-MS with derivatization
Complexometric titration or colorimetric test
DCM extraction, FTIR quantification at 1260 cm-1
Ethylene glycol by GC-FID after extraction
Direct pH measurement at 25°C with calibrated electrode
Hexane extraction, LC-MS analysis
Multiple cycles per customer, gravimetry
Recovery validation with hydrocarbon standard, GC-MS method
Quantitative analysis for single element after extraction
XRF elemental screening for RoHS compliance
LC-MS/MS for PFAS compounds (EU list)
Water extraction 72h at 37°C, HS-GC-MS analysis
Conditions per customer, Tenax extraction, GC/LC-MS
GC-MS quantification in CBD products
ICP-MS analysis for heavy metals suite
Evaporation of extract, gravimetric determination
Acid digestion, ICP-MS for heavy metals
Surface elemental analysis at 3 locations, depth <10nm
Additional element quantification by ICP-MS
Conditions per customer in simulant, gravimetric analysis
Extraction in DMF, GC-FID quantification
IPA extraction 72h at 37°C, GC-MS screening
Multiple cycles per customer, Tenax, GC/LC-MS
GC-MS for cannabinoid profile
UV spectrophotometry or ion chromatography
ATR-FTIR spectrum comparison with reference
Conditions per customer in oil simulant, gravimetry
Particle extraction, SEM imaging + EDX elemental mapping
Gravimetric analysis of residual water on devices
Additional extraction cycle for EO/ECH
GC-MS extraction method
Hexane extraction 72h at 37°C, GC-MS analysis
Conditions per customer, gravimetric determination
Titration of aqueous extract
Extraction in particle-free water, light obscuration counting
Simulated use extraction, GC-FID headspace analysis
Multiple cycles per customer in oil, gravimetric analysis
Additional SEM-EDX analysis on subsequent samples
Water extraction, LC-MS screening for non-volatiles
Volatile siloxane migration test on Tenax